It will only run when fully choked. Honda EU2000i won't start! Need Help!!! I have only got about 3 months of heavy use on this unit and it has performed flawlessly, starting on the first pull every time. I’ll choke or no choke or no throttle or 1/2 or full with all positions of the choke and nothing. It's alive! Honda eu2000i generator on the cheap A Honda eu2000i in unknown, "non-running" condition for $200. Some times a back fire into the carburetor will blow a pressed-in BB out of a drilled passage way. Honda EU1000i Portable Generator product reviews by real people like you. Find ONAN SISSON CHOKE 153-0223 - NEW OLD STOCK. This Honda generator is so reliable that we cover it from top to bottom, for three years. Have a Honda Generator with a GX140 engine on it. However, like any power equipment, they can still experience issues. of fuel Fuel- efficient - runs up to 18 hours on 5. Buying Honda Generator - With a wide variety of quality options available, purchasing a honda generator involves the consideration of several factors. When it is not choked it is starving for fuel runs very rough and the ecco throttle does not work. The technical details are as follows, from the Honda EU2000I manual: 120V 2000W max. Purchased new in 2015. 95 US gal. ME-AGS-S Wiring Diagram - for Honda (EU3000is) Generators 11-8-2011 5 amp fuse 5 amp fuse Magnum Energy, Inc. Let the throttle move off of idle and it dies. I agree that the battery charger function on the EU2000i is not very interesting. the HF also has the eco throttle just like the honda. The fault code 36 only informs that the genset shut down by itself. Carburetor rebuilding procedure. Anyone out there have any suggestions? Thanks in advance. Have used it a lot over 600 hrs. I asked why over a Honda. 7A for roughly 30 minutes, it’s not designed for continuous use at these ratings. The last 6 yrs or so vent must be leaking by a bit preventing the vacuum generation needed to run the carb dry so I have been storing wet. As usual, the carb tear down showed the mess this stuff leaves after it evaporates. I gave it another small squirt and it started again but this time it stayed running on full choke. The generator won’t start. able of ContentsT Safety Information >>>>> 1. The 3rd day, I ran the Honda for only a few hours, then let the solar panels take over from there on out. However, like any power equipment, they can still experience issues. I could not start either this last week at -38F without warming them up. PORTABLE PERFORMANCE. Honda EU2000I (A) Generator, Jpn, Vin# Eaaj-1000001 To Eaaj-1036877 Parts Only runs with the choke on. Last winter I purchased a used Honda EU2000i inverter genset it seemed to run well when the seller demo'd it but once I actually got to play with it myself at home I found it was really struggling to run smoothly with the choke fully off. For parallel operation, use only a Honda approved parallel operation cable kit (optional equipment) when connecting one EU2000i to either an EU2000i Companion or another EU2000i generator. The Honda eu2000i--1,600 watts, 1. Honda OPE hate ethanol. Exceptionally efficient, it can run 7. The eu3000is can operate a wide variety of appliances, making it perfect for use at home or camping. I was thinking about filling the tank with new fuel and some kind of additive and just letting it run. The throttle system present in this generator is used to controls the speed of the engine depending on the needed load by making the generator engine to work. But no problems. It does run pretty good across the spectrum of adjustment, but better towards the closed side of adjustment. They told me thats just how they run. While I'm trying to figure out the previous question, can you confirm that the "11 oclock" position is correct for the Honda EU2000i? That looks right as far as the gasket, but also looks like the snorkel would be compressed against the white choke bracket. The trailer has a 15,000 BTU AC unit and this generator starts and runs it with out any problems. It cannot run on propane, or natural gas, as a fuel source without modification. I have run them at 10000' and they started fine with stock jets. Never connect different generator models. Like most portable generator using the Honda EU2200i is easy. Advanced inverter technology - reliable power for computers and other sensitive equipment: Honda's inverter technology means stable, clean power in a smaller, lighter package. 2 to 20 hours on a single tankful of gasoline, depending on the load. I use my KX3 primarily for operating portable at various locations, usually outside but not always. Quick Shipment. Changed oil annually, no other maintenance. Don’t run your generator the entire time you’re camping. This buy it now is for an onan choke. Re: Honda EM 2200X Genset engine will only run with the choke closed If it is the same motor as mine you will see a screw/plug on the top of the venturi directly above the main jet tube. my buddy has the honda, and with both generators running and standing between our rv they are the same dB in my opinion. 9 inch that makes it easier for you to grab and go. Sometimes, I do have grid supplied power, most other times. Honda or Yamaha. Changing the Spark Plug on a Honda EU2000i Generator. I took it to the dealer and the took the carb off cleaned it and still same problem. It requires 12 amps at start up. I immediatly connected to NG. Car and Truck Parts by Make and Model. The price on this generator is a hefty $2,750. Honda's advanced inverter technology provides 1000-Watt of extremely quiet, clean and fuel-efficient power. It's in the top 3 bestselling portable generators and has dozens of popular alternatives in the same price range, such as Cat RP3600 or Ryobi RYi2200GR. but a new set of rings is only $15, so it'd be. Honda generators are extremely robust and designed to withstand tough working conditions. considering I'll be. 3 lbs, the EU2000i utilizes Honda's "state of the art" inverter technology to provide 2000 watts of lightweight, quiet and efficient power. able of ContentsT Safety Information >>>>> 1. Open the choke and it dies. It sat in my shed until this summer when I pulled it out put it together and put all fluids in and tried to start it. You will not know if the BB is missing cause it will look like another hole in the carburetor. Portable Generator Propane Conversion Kits & Natural Gas Conversions for Generators, Concrete Saws, & Welders. As a premium Generators products, Honda EU3000 EU3000i. Honda EU3000IS Generator Surging / Pulsing Problem Bought this generator new a couple of years ago and always drained the gas or used stabil and ran every year multiple times. Honda EU2000i series generators are regularly used by individuals on campsites and RV sites due to its very quiet operation. It does run pretty good across the spectrum of adjustment, but better towards the closed side of adjustment. • For parallel operation, use only a Honda approved parallel operation cable kit (optional equipment) when connecting one EU2000i to either an EU2000i Companion or another EU2000i generator. It only runs with the choke on. Have a Honda Generator with a GX140 engine on it. I toyed with the idea of the Honda 3000 but that is only 120v too so it would just mean more fuel consumption. Right now I'm modifying a propane burner for my giant cooking pot. I will guess the EU2000i runs "smoother" with the Choke ON, is that right? Does it run a little rough with the Choke OFF? If so, these are classic symptoms of a partially clogged main jet or nozzle inside the carburetor. Honda EU2000i Inverter Generator LOCAL PICK UP ONLY!!!!! Dual Fuel Generator Carburetor For Honda GX390/188F/5KW AUT Choke LPG NG Petrol 1x Carburetor Generator For Honda GX390 188F 5KW AUT Choke LPG NG Petrol Part Extended Run Fuel Gas Tank Cap Adapter For Honda Generator EU2000i EU3000i 1000i. The fact that it runs well half choked, tells me that the carb has a either a plugged main jet, or gum in the fuel. Honda Generator will not start out of storage, tips and tricks to fix a non-working generator. Only thing is, I'd like to get it dialed in nice. Honda Eu2000i only runs on choke discussion in the Tool Talk forum at Yesterday's Tractors. It would stall as soon as turned the choke off. It’s hard to provide the accurate reviews of inverter generators without making at least a few references to Honda generators. We need the 2 generators connected together in parallel to give us sufficient startup power. Very good on fuel too. How to fix your Honda EU2000I. Free online Repair Guides and help from our Generator Engineers. Generac GP2200i vs Honda EU2200i. Re: EU2000 Honda generator troubleshooting At the time there wasn't an overbore kit available so it was done. or 120 Volts only. Today I installed the Pinellas Products remote start/auto choke kit on my Honda EU3000is. It’s a little over poppy on the decel…( I expect some ) and the fuel mixture screw can be all the way seated and it doesn’t slow down idle. Hope that helps,. Open Range RV Owners Forum Will the Honda EU2000i inverter generator run the small 13. Runs between 6 to 18 hours on a single tank, depending on the load. So, with a constant load of 2000W it will trip the overload. It's environmentally-friendly with low emissions, less noise and lower fuel consumption than its two-stroke counterparts, and can run up to 8. Carb-cleaning, Air Filter, Oil Change, Spark Plug (see the photos). 1 gal of fuel the reliable Honda GX390 engine is designed. Only thing is, I’d like to get it dialed in nice. I was happier to have used a US Carburetion conversion kit to run it off of natural gas. I'll choke or no choke or no throttle or 1/2 or full with all positions of the choke and nothing. I have run them at 10000' and they started fine with stock jets. Found that it would run in the ECO mode with the choke about half on. Exceptionally efficient, it can run 7. However, it may be too expensive for some users. My generac starts without even getting a complete pull, full choke, deadcold, anytime except when it runs out of gas. Store with carb dry. Today I installed the Pinellas Products remote start/auto choke kit on my Honda EU3000is. • For parallel operation, use only a Honda approved parallel operation cable kit (optional equipment) when connecting one EU2000i to either an EU2000i Companion or another EU2000i generator. Now it only ran with full choke and pressed in hard and held there for a bit. It should have no effect on the UTS10BI. 1 gallons of fuel = 5. My buddy just bought a Yamaha. The Honda's would only run for 8 hours before they needed refueling. I could not start either this last week at -38F without warming them up. Then it ran out of gas, and after filling it up it would not start. Installed the new carb and everything works as it should. Honda's advanced inverter technology provides 3,000-Watt of extremely quiet and fuel-efficient power. This popular, exceptionally portable model can operate a wide variety of small appliances, such as lights, fans, tv's, computers, blenders, etc. My Honda EU2000i generator will only run when I have the lever left on 'choke' after starting. I cleaned the carb in an ultrasonic cleaner, and it ran great after that. Honda HRX217 Fabric Grass Bag Replaces Honda 81320-VH7-D00 - Fits Honda Models HRX217K2, HRX217K2, HRX217K2, HRX217K3, HRX217K3, HRX217K3, HRX217K4, HRX217K4, HRX217K4 and HRX217K4 - Bag Only No Frame - Fits Honda HRX217 Models that have a bagger frame that folds up when bag is not installed. Runs between 6 to 18 hours on a single tank, depending on the load. The eu3000is can operate a wide variety of appliances, making it perfect for use at home or camping. RR135V6_10/06/2019_MS-N. Generac GP2200i is a very popular option on the higher end of the price range. Features The Honda EU7000is generator incorporates the company's first application of electronic fuel injection into the design of a generator, resulting in greater fuel efficiency, extremely easy starting without the need for a choke, and longer running times than the EU6500is model it replaces. $4 a Day - Yamaha's new EF2000iS portable generator Accessories Hi-lite — By sbutera on May 10, 2011 at 7:03 pm. Now it only ran with full choke and pressed in hard and held there for a bit. Which 2000W Honda? The red EU2000i inverter unit? If so, I have one of those. I gave it another small squirt and it started again but this time it stayed running on full choke. This makes it great for overnight power. The EU7000iS can operate a wide variety of appliances, making it perfect for portable use at home, camping, or much more. For parallel operation, use only a Honda approved parallel operation cable kit (optional equipment) when connecting one EU2000i Companion to either an EU2000i or another EU2000i Companion generator. for Honda EU2000i Generator Extended Run Gas Cap,DipStick, & Oil Funnel Set. Honda Snorkel Propane Natural Generators Tri Fuel Conversion Kit Smaller | eBay Replace the air filter gasket with the Motor Snorkel. Choose between using both 120 and 240 Volts, or 120 Volts only. If you aren't an expert on generators, looking into buying one can be extremely confusing, especially since there are multiple types of generators made by many different brands. Changing your spark plug will. This generator has maybe 100 hours on it and I use it maybe 15-20 hours a year and run it for 30 minutes a month when it is not being used. When I prime it it starts for a few seconds then dies. These are the most common Honda generator problems we see. Honda EX350 generator mystery, please help (just like you were putting the choke on), then goes back up to normal rpm. He does not exercise it enough, and the fuel is too old, but after the one experience with the gummed up carb, he goes out of his way to find real gasoline, not the gasahol forced upon the nation. This Honda generator is so reliable that we cover it from top to bottom, for three years. Great engines when they are working right. Removed the carburetor and cleaned the dickens out of it with carb/choke cleaner in the aerosol can several times then used hot water and dried it with air pressure. Fuel efficient - runs up to 18 hours on 5. 5 cc engine which lets it produce 1600 watts of continuous power while being able to surge up to 2000 watts. Honda EU2000i product reviews by real people like you. 1* hours of continuous operation on a full fuel tank. I can only assume this procedure is the same for the EU1000. The exhaust system gets hot enough to ignite some materials. I can run 2 Skil saws at the same time. I was thinking about filling the tank with new fuel and some kind of additive and just letting it run. i run mine with an EU2000i. This is on the EU2000i I bought it the second year they came out. The owner said it sat outside in the rain 1 night and it didn't start the next morning and it had spark until he sprayed berryman carb cleaner in it. Shop with confidence. I winterize it every year and have had no trouble except for this year. Find ONAN SISSON CHOKE 153-0223 - NEW OLD STOCK. Quick Shipment. Store with carb dry. Kawaguchi Honda, Los Angeles, CA, (323) 264-3936 is here to answer your questions and help with your tailgating needs. Skip to main content. It will run for at least 4 hours at its rated load of 1600 watts. The good news is, the Honda EU2000i is the one you are looking for. If you have been in search of a camping generator that emits little noise, then you should consider this Honda EU2000i Inverter Generator as it is the quietest 2000Watts generator. I'm just saying that if they are trying to sell it as a 400$ gen/inverter then it had better start like such. At only 46lbs, you can take portable power wherever you go. Go out to garage and find another project to do that is useful and helps with prepping. We Sell Only Genuine Honda ® Parts. I like the controls, the output connections and the variety of ways the generator can be started and stopped. The exhaust system gets hot enough to ignite some materials. This makes it great for overnight power. New Look, Same Great Ownership. It started with a small 400 W to 1 KW (EX 1000) to the current EU2000i. 5 hours without refueling (at 1/4 rated load with "Economy Control" function on. Honda EU2000i 2000 Watt Portable Generator is super quiet, fuel efficient, and portable. When we moved up to the old ranch house, believe it ir not we ran it using those generators; length of time dependant on occupancy during the day/night. Engine Starts with starter fluid, but won't stay running determined the engine runs, but this is a Honda and they make one of the best engines in the world so if. EU2000i (Silver, Honda Generator logo. It purrs with the choke open and the ecco throttle works when it is choked. It's as reliable as most Honda products and comes with a 3-year warranty. I asked my husband about your problem and he said that he would check your spark plug to see if it's wet after the engine stalls. Shop with confidence. Watch our video on how to replace the spark plug on a Honda EU2000i generator. Shop online for OEM CARBURETOR parts that fit your Honda Power Equipment EU2000I A - EAAJ 1000001-1036877, search all our OEM Parts or call at (231)737-4542. I took it to the dealer and the took the carb off cleaned it and still same problem. However, like any power equipment, they can still experience issues. 1 gallons of fuel = 5. The EU3WS2 also features a temperature sensitive auto-choke providing a slow release choke at 32F or colder. Honda Outdoor Power Equipment. When boon-dock camping at our hunting club, my Honda is by-far the quietest generator there, and by-far the most fuel efficient. PORTABLE PERFORMANCE. The EU2000i can only support the maximum output of 2. Try to crank again with choke on. Possible causes for a Honda generator not starting are:. Portable Generator Parts Specialists stocking 500,000+ parts for over 800+ brands of portable electricity generators. The shape and design remain intact though but the housing is now accentuated with orange, replacing the bright yellow accents on the old design. It has a fuel tank capacity of 1. 1 hours of operation on 1 tank of fuel. It would not run at all if I moved the choke. He does not exercise it enough, and the fuel is too old, but after the one experience with the gummed up carb, he goes out of his way to find real gasoline, not the gasahol forced upon the nation. Honda EU2000i owner’s manual. - Engine Oil. It is the #1 selling Honda generator (i think). It will run with the choke half way on. but a new set of rings is only $15, so it'd be. Don't worry about someone sawing through the handle to steal your unit. 10-W-30 is the standard all-temperature motor oil recommended by Honda for its generators. The Honda EU2000i - 1600 Watt Portable Inverter Generator EU2000IA1 has been discontinued. Normal was running good. Any tips on starting a generator in the cold? I have 1000W Honda and 2000W Yamaha. The EU22i starts 'first time every time' with Honda's reliable one pull easy start system. 95 US gal. Started up my eu2000i gen set today and it was surging like crazy in the ECO mode. New In-Depth Outdoors TV. com - Select Honda EU3000IS AC - Honda Generator, 3000 watts, Made in Japan, SN: EZGF-1080001 Diagrams and order Genuine Honda. It has eco throttle which is the same idea. I can run 2 Skil saws at the same time. Despite being treated with Marine Stabil, my EU2000I would only run with the choke being partially on. The good news is, the Honda EU2000i is the one you are looking for. I can never take it off or it hunts or runs rough again. Specs are listed in attached picture. It’s running a lot smoother now. Find Honda Generator in Canada | Visit Kijiji Classifieds to buy, sell, or trade almost anything! New and used items, cars, real estate, jobs, services, vacation rentals and more virtually anywhere in Winnipeg. We are an exclusive Honda Powersports Dealer for over 50 years located in Scottsdale Arizona, consistently offering the best value, pricing and service to our loyal Honda fan base. Little single cylinder Honda generator. I keep one in the Honda in the truck to start it, but I couldn't get the Honda started for the life of me. At 7000' running my microwave with one generator the voltage is about 98V! Running the same generator at sea level produced about 110V with the same microwave. Took carb off to clean junk out. I realized that he assumes by the name that the generator delivers 2000 running Watts. It's alive! Honda eu2000i generator on the cheap A Honda eu2000i in unknown, "non-running" condition for $200. When I prime it it starts for a few seconds then dies. Some times a back fire into the carburetor will blow a pressed-in BB out of a drilled passage way. Works flawlessly, starts easily, even after being unused for 6 months. This post is about the generator portion of that plan. We Sell Only Genuine Honda ® Parts. I winterize it every year and have had no trouble except for this year. Runs between 6 to 18 hours on a single tank, depending on the load. Had it powering. 5 cc engine which lets it produce 1600 watts of continuous power while being able to surge up to 2000 watts. -Fuel efficiency: I had some concerns about getting through a summer night on one tank of gas since specs say that it’ll run for only 7 hours at full rated capacity. Honda EU2000i choke issue. This buy it now is for an onan choke. It took about 5 hours. The ONLY US Patented Honda EU1000 Tri-Fuel Kit! T he revolutionary design ofour newly patented Motor Snorkel (05/2013) for the UE2000i allows this Honda Generator to run on Tri-Fuel WITHOUT DRILLING THE CARBURETOR AND VOIDING THE MANUFACTURES WARRANTY!. The Argument $4 a day. Ryobi RYi2200: My judgement. Last year i got a EU2000i Companion to work with the EU2000i. I tried once with direct plug in to generator but cut out when on load. Again, as the previous post stated, keep it tuned and serviced. This generator comes with two 120V, 13. Half the cost of a Honda but came DOA and I had quite a time getting them to send me a new inverter unit. At 7000' running my microwave with one generator the voltage is about 98V! Running the same generator at sea level produced about 110V with the same microwave. from what i have heard, the engine has to come completely apart to replace the darn thing, as it comes out. If you have this genny,and it surges or wont run without choke on,here is an excellent pictorial a guy did on how easy it is to fix. How to fix your Honda EU2000I. of fuel Thanks to our exclusive Eco-Throttle System, the EU7000iS offers great fuel efficiency. Honda EB 5000X generator repair. Honda engines seem to start better with a good clean air filter. Very disappointed. The seller bought it four years ago and ran it only to check it. Purchased new in 2015. Had an issue with our EU2000i where it would only run with the choke on. This makes it great for overnight power. Previously it occurred only when the motorhome was underway, but recently it happens with the motorhome parked. This makes it great for overnight power. Installed the new carb and everything works as it should. Advanced inverter technology - reliable power for computers and other sensitive equipment: Honda's inverter technology means stable, clean power in a smaller, lighter package. As for power, my buddy can run everything he has in his 24ft hybrid (13. The generator won't start. 00 or best offer. Plus, advanced inverter technology provides clean, stable power for running sensitive electronics. I cleaned the carb in an ultrasonic cleaner, and it ran great after that. Very disappointed. •Never connect different generator models. Perfect for home back up power, RVs, outdoor events, and more. Honda EU2000i product reviews by real people like you. The EU3WS2 also features a temperature sensitive auto-choke providing a slow release choke at 32F or colder. Usually run it on premium gasoline without ethanol, at elevations up to 11,000 feet. They told me thats just how they run. Extended Run Fuel Cap & Funnel For Honda. the low oil shutdown thing with honda is its one and only weak link in my opinion. The Eco-Throttle™ system empowers the Honda EU2200i Portable Generator to run up to 8 hours while consuming only 1 gallon of fuel. I'll choke or no choke or no throttle or 1/2 or full with all positions of the choke and nothing. Got a new Honda eu2000i to run my home furnace here in the NorthWest. The good news is, the Honda EU2000i is the one you are looking for. I purchased the Honda EU2000I for the sole purpose of running my furnace when the power goes out. I drained the carburetor and it didn't seem to help. If you plan on having a plasma TV and an electric grill, you’ll need a portable generator. Only 1 left! 23 Sold 23 Sold. The eu3000is can operate a wide variety of appliances, making it perfect for use at home or camping. Don’t run your generator the entire time you’re camping. I can never take it off or it hunts or runs rough again. Dual Honda Eu2000i Generator Feed Tank. The Honda's would only run for 8 hours before they needed refueling. I thought I would include a report of success in case it helped someone in the future. The seller bought it four years ago and ran it only to check it. The only instructions are on video, so you have to watch part of the video, stop, complete those instructions and move on to the next task. I watched a YouTube video of a customer complaining about his new Yamaha ef2000isv2 being unable to power an 1800 Watt hairdryer. 6 gallon tank on an eu1000i verses 9. * Note: If you have an automatic choke try disabling the choke and holding it all the way open with a zip tie or other device. It’s hard to provide the accurate reviews of inverter generators without making at least a few references to Honda generators. If it is wet, the carburetor might be delivering too much fuel and flooding the engine. Powermate 2200W is $500. 2 gallon fuel tank allows 10. Still left the choke on. 13 results for used honda generator Save used honda generator to get e-mail alerts and updates on your eBay Feed. It’s running a lot smoother now. Took carb off to clean junk out. Beam Regulator, Garretson Demand Regulator & Impco propane carburetors. Purchased new in 2015. Features The Honda EU7000is generator incorporates the company's first application of electronic fuel injection into the design of a generator, resulting in greater fuel efficiency, extremely easy starting without the need for a choke, and longer running times than the EU6500is model it replaces. I cleaned the carb in an ultrasonic cleaner, and it ran great after that. We now have 3 Honda eu2000i's at camp and mine is 4 years old. Last winter I purchased a used Honda EU2000i inverter genset it seemed to run well when the seller demo'd it but once I actually got to play with it myself at home I found it was really struggling to run smoothly with the choke fully off. Finally go to use it, and when the unit is on full throttle it surges, runs smooth then drops down and surges back and does this ever other couple of seconds. The Honda EU2200i runs on 2,200 watts, which is the power you will need for a campsite, job site, or event at home. The seller bought it four years ago and ran it only to check it. The machine ran well for a short. It's alive! Honda eu2000i generator on the cheap A Honda eu2000i in unknown, "non-running" condition for $200. Re: Honda EM 2200X Genset engine will only run with the choke closed If it is the same motor as mine you will see a screw/plug on the top of the venturi directly above the main jet tube. Carb bowl and jet are very clean, now what? - Answered by a verified Technician. The whole process took about 60 minutes. All of my other small engines have a gas shutoff valve, which I use to run all the gas out of the carb and avoid this problem. Before turning off the A/C, I inadvertently took one generator offline causing the A/C unit to run off only one generator with no issues. It only runs with the choke on. of fuel Fuel- efficient - runs up to 18 hours on 5. Installed the new carb and everything works as it should. New Look, Same Great Ownership. ME-AGS-S Wiring Diagram - for Honda (EU3000is) Generators 11-8-2011 5 amp fuse 5 amp fuse Magnum Energy, Inc. It holds only a couple of quarts, but that's nearly enough for all day. It means that the engine is not required to run at full speed continuously. Works flawlessly, starts easily, even after being unused for 6 months. I run this genset every month under full load for an hour and it has less than 200 hours on it.